As the temperature drops and leaves begin to fall, there exists a fleeting interlude, sandwiched between the sweltering summer heat and the impending winter frost that provides a golden opportunity to conduct a bit of semi-annual cooling tower maintenance. Because, whether used in the confines of hospitals or universities – data centers, manufacturing processes, or simply comfort cooling, one truth remains steadfast – the maintenance of cooling towers is pivotal for unceasing operational excellence. In this guide, we will outline essential steps to preserve the efficiency and reliability of cooling towers during the autumn season.

Thorough Inspection

Kickstart your autumn maintenance routine with a comprehensive inspection of your cooling towers. Look out for signs of wear, corrosion, loose connections, or pipe leaks. Pay particular attention to vital components like the tower structure, fill material, fans, and motor assemblies. Identifying and addressing issues promptly can prevent costly breakdowns in the future.

Basin Cleaning

Over time, debris such as leaves, twigs, and dirt can accumulate in the cooling tower basin, impeding water flow and reducing cooling efficiency. Before the onset of winter, ensure the basin is free from debris and undergoes a thorough cleaning. A clean basin guarantees unhindered water circulation, preventing potential freezing problems during colder weather.

Water Treatment Systems

Water quality is crucial for optimal cooling tower performance. Scrutinize water treatment systems, including chemical feeders and filtration equipment. Ensure that chemical levels fall within recommended ranges to prevent scale buildup, corrosion, and biological growth. Maintain water quality by cleaning or replacing filters as required.

Lubrication of Moving Parts

Cooling towers contain several moving parts, such as fan motors, bearings, and drive shafts. Proper lubrication is indispensable to reduce friction, extend component lifespan, and prevent excessive wear. Consult the manufacturer’s guidelines for the correct lubricants and intervals, and apply lubrication before colder temperatures set in to ensure seamless operation.

Belt Tension and Alignment

In cases where belts drive fan motors, scrutinize the belts for wear, tension, and alignment. Replace worn or damaged belts and make necessary tension adjustments to prevent slippage. Misaligned belts can diminish fan efficiency, resulting in increased energy consumption and reduced cooling capacity.

Testing Controls and Sensors

Verify the correct functioning of all control systems, sensors, and switches. Rigorously test the thermostat, pressure switches, and float switches to confirm their accuracy. Address any malfunctioning components through calibration or replacement to maintain precise temperature control and system dependability.

Drift Eliminator Inspection

Drift eliminators capture water droplets carried by the exhaust air, preventing water loss and potential waterborne contamination. Inspect these eliminators for damage or obstructions and replace any defective sections. A well-maintained drift eliminator contributes to water conservation and system efficiency.

Safety Features Review

Safety should perpetually top the priority list. Inspect all safety features, including guards, railings, and access doors, to ensure their stability and condition, minimizing the risk of accidents during maintenance or routine inspections.

Preparing for Winter

As autumn progresses, consider implementing winterization measures to safeguard your cooling towers from freezing temperatures. Depending on your climate and equipment specifications, this may involve installing freeze protection devices or draining the system.

Documentation and Record-Keeping

Maintain meticulous records of all maintenance activities, including inspections, repairs, and replacements. This comprehensive documentation serves as a valuable tool for monitoring the system’s performance over time and planning forthcoming maintenance tasks.

——————————————————————————————————————–

Trust Dyna-Tech

Do you need cooling tower parts, service, or inspections? Are you considering refurbishing your cooling system or replacing it all together – or maybe you just want to talk to someone about advancements in cooling technology, system efficiency and current industry standards?

If so, give us a call at 908-541-1010 or click on the (contact us) link at the bottom of the page. Our sales engineers are ready to answer your questions and discuss your needs.